If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
MCC TM Micro Commercial Components omponents 20736 Marilla Street Chatsworth !"# $ % !"# 182KD14JX* thru 180LD14JX* 11 to 1000 Volts Varistor 5.2 to 510 Joule Features * * * * * High Surge, High Energy Designed to be Operated Continuously Across AC Power Lines No Derating Up to 85 Ambient Available in Tape and Reel or Bulk Pack UL Recognized File # E306895(UL1449) and E306942(UL1414) Maximum Ratings * * * * Operating Ambient Temperature Range: -55 to +85 Storage Temperature Range: -55 to +125 Temperature Coefficient ( V) of Clamping Voltage (VC) at Specified Test Current:<0.05%/ Varistor voltage temperature coefficient: Vb at 25 - Vb at 85 Vb at 25 x 1 x(100/ 60 ) Kink Lead 120 100 80 60 L: 20mm Min. DIMENSIONS Unit: mm Size D max H max S 11 13 18 22 28 C/I/Y 13 15 19.5 23 30 D 0.05 All 0.6 0.6 0.6 0.8 0.8 1 0.8 1 E 1.0 All 5 5 5 7.5 7.5 10 7.5 10 40 20 Lead 05D 07D -55 60 80 100 120 140 160 All 7.5 9 12.5 16.5 23 0 10D 14D 20D AMBIENT TEMPERATURE (C) PERCENT OF RATED VALUE CURRENT, ENERGY AND POWER DERATING CURVE Note : 'X' can be S, C, I or Y . 'S' 'C' 'I' 'Y' denotes denotes denotes denotes straight lead out crimped lead inner crimped lead kink lead * www.mccsemi.com Revision: 2 1 of 6 2006/09/09 182KD14JX thru 180LD14JX MCC Withstanding Surge Current 8/20us Rated Wattage Varistor Voltage Maximum Clamping Voltage V50A (V) 2970 1815 1650 1500 1355 1290 1240 1120 1025 920 845 775 710 650 595 550 505 455 395 360 330 300 250 200 165 135 *135 *110 *93 *77 *65 *53 *43 *38 TM Micro Commercial Components Electrical Characteristics @ 25OC Unless Otherwise Noted Maximum Allowable Voltage Part Number ACrms (V) 182KD14J X 112KD14J X 102KD14J X 911KD14J X 821KD14J X 781KD14J X 751KD14J X 681KD14J X 621KD14J X 561KD14J X 511KD14J X 471KD14J X 431KD14J X 391KD14J X 361KD14J X 331KD14J X 301KD14J X 271KD14J X 241KD14J X 221KD14J X 201KD14J X 181KD14J X 151KD14J X 121KD14J X 101KD14J X 820KD14J X 680KD14J X 560KD14J X 470KD14J X 390KD14J X 330KD14J X 270KD14J X 220KD14J X 180LD14J X 1000 680 625 550 510 485 460 420 385 350 320 300 275 250 230 210 195 175 150 140 130 115 95 75 60 50 40 35 30 25 20 17 14 11 DC (V) 1465 895 825 745 670 640 615 560 505 460 418 385 350 320 300 275 250 225 200 180 170 150 125 100 85 65 56 45 38 31 26 22 18 14 10/1000us (J) 510 310 283 255 235 233 230 225 215 205 190 175 155 140 130 115 105 99 84 78 70 65 53 44 36 28 20 16 14 11 9.5 7.8 6.3 5.2 2000 1000 0.1 6000 4500 0.6 1 time (A) 2 times (W) (V) 1800(1620-1980) 1100(990-1210) 1000(900-1100) 910(819-1001) 820(738-902) 780(702-858) 750(675-825) 680(612-748) 620(558-682) 560(504-616) 510(459-561) 470(423-517) 430(387-473) 390(351-429) 360(324-396) 330(297-363) 300(270-330) 270(243-297) 240(216-264) 220(198-242) 200(180-220) 180(162-198) 150(135-165) 120(108-132) 100(90-110) 82(74-90) 68(61-75) 56(50-62) 47(42-52) 39(35-43) 33(30-36) 27(24-30) 22(20-24) 18(15-21) V1mA Maximum Energy *680K-180L Max. Clamping Voltage testing current 10A. www.mccsemi.com Revision: 2 2 of 6 2006/09/09 182KD14JX thru 180LD14JX MCC Max. Clamping Voltage 680KD14 560KD14 470KD14 390KD14 330KD14 270KD14 220KD14 180LD14 TM Micro Commercial Components V-I Curve (180L to 680K) 400 300 200 150 100 90 80 70 60 V 50 20 680KD14 560KD14 470KD14 390KD14 330KD14J 270KD14 220KD14 180LD14 Test current waveform -6 -3 10 to 10 A: Direct current -1 4 10 to 10 A: 8/20s 10 -6 Max. Leakage Current 10 9 6 5 10 -5 10 -4 10 -3 10 -2 10 -1 10 0 10 1 10 2 10 3 104 105 A V-I Curve (820K to 561K) Max. Leakage Current Max. Clamping Voltage 561KD14 511KD10 471KD14 431KD14 391KD14 361KD14 331KD14 301KD14 271KD14 241KD14 221KD14 201KD14 181KD14 151KD14 121KD14J 0 101KD14 820KD14 100 90 80 70 60 50 40 30 10 -6 2000 1000 900 800 700 600 500 400 300 V 200 Test current waveform 10-6 to 10-3 A: Direct current -1 -4 10 to 10 A: 8/20s 10 -5 10 -4 10 -3 10 -2 10 -1 10 0 10 1 10 2 10 3 10 4 10 5 A www.mccsemi.com Revision: 2 3 of 6 2006/09/09 182KD14JX thru 180LD14JX MCC Max. Clamping Voltage 182KD14 152KD14 112KD14 102KD14 911KD14 821KD14 781KD14 751KD14 681KD14 621KD14 TM Micro Commercial Components V-I Curve (621K to 182K) 5000 Max. Leakage Current 4000 3000 2000 V 1000 700 600 500 400 300 200 10 -6 Test current waveform -6 -3 10 to 10 A: Direct current -1 4 10 to 10 A: 8/20s 10 -5 10 -4 10 -3 10 -2 10 -1 10 0 10 1 10 2 10 3 10 4 10 5 A V-I Surge Life Time Ratings (180L to 680K) 10000 10000 V-I Surge Life Time Ratings (820K to182K) 1 time 2 times 1000 1 time 2 times 10 times A 100 10 times 10 times 105 times 10 times 10 10 times 6 4 3 2 1000 10 times 10 times 10 times 3 2 A 100 10 times 10 times 10 times 6 4 5 10 20 1000 s Impulse Current - Amperes Impulse Width - Micro seconds 100 10000 20 1000 s Impulse Current - Amperes Impulse Width - Micro seconds 100 10000 www.mccsemi.com Revision: 2 4 of 6 2006/09/09 182KD14JX thru 180LD14JX MCC T Thickness D10 12.6 10.5 9.9 9.4 8.3 8.1 8.8 8.6 8.4 8.0 7.6 7.3 7.0 6.8 6.5 5.7 5.5 5.3 5.2 5.0 4.8 4.7 4.6 4.5 4.9 4.5 4.4 4.3 6.0 5.5 5.5 5.1 5.1 5.1 4.9 4.9 TM Micro Commercial Components Note 2. (max.) Unit : mm D14 12.8 10.7 10.1 9.6 9.0 8.8 8.6 8.2 7.8 7.5 7.2 7.0 6.7 5.9 5.7 5.5 5.4 5.2 5.0 4.9 4.8 4.7 5.1 4.6 4.5 4.4 6.1 5.6 5.6 5.2 5.2 5.2 5.0 5.0 Part Code 182K 112K 102K 911K 821K 781K 751K 681K 621K 561K 511K 471K 431K 391K 361K 331K 301K 271K 241K 221K 201K 181K 151K 121K 101K 820K 680K 560K 470K 390K 330K 270K 220K 180L D05 D07 D20 13.5 11.2 10.7 10.1 9.5 9.3 9.1 8.7 8.3 8.0 7.7 7.5 7.2 6.4 6.2 6.0 5.9 5.7 5.5 5.4 5.3 5.2 5.6 5.3 5.1 4.9 6.1 5.6 5.6 5.4 5.4 5.4 5.3 5.2 7.9 7.5 7.2 6.9 6.6 6.4 6.1 5.3 5.1 4.9 4.8 4.6 4.4 4.3 4.2 4.1 4.5 4.1 3.9 3.8 5.5 5.0 5.0 4.7 4.7 4.7 4.5 4.5 7.9 7.5 7.2 6.9 6.6 6.4 6.1 5.3 5.1 4.9 4.8 4.6 4.4 4.3 4.2 4.1 4.5 4.1 3.9 3.8 5.5 5.0 5.0 4.7 4.7 4.7 4.5 4.5 www.mccsemi.com Revision: 2 5 of 6 2006/09/09 MCC Micro Commercial Components TM ***IMPORTANT NOTICE*** Micro Commercial Components Corp . reserves the right to make changes without further notice to any product herein to make corrections, modifications , enhancements , improvements , or other changes . Micro Commercial Components Corp . does not assume any liability arising out of the application or use of any product described herein; neither does it convey any license under its patent rights ,nor the rights of others . The user of products in such applications shall assume all risks of such use and will agree to hold Micro Commercial Components Corp . and all the companies whose products are represented on our website, harmless against all damages. ***APPLICATIONS DISCLAIMER*** Products offer by Micro Commercial Components Corp . are not intended for use in Medical, Aerospace or Military Applications. www.mccsemi.com Revision: 2 6 of 6 2006/09/09 |
Price & Availability of 471KD14JX |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |